covidien kendall scd 700 series user manual
Covidien Kendall SCD 700 Series User Manual: A Comprehensive Guide
This comprehensive guide details the Covidien Kendall SCD 700 Series, offering instructions for safe and effective operation, maintenance, and troubleshooting of this medical equipment.
The Covidien Kendall SCD 700 Series represents a significant advancement in sequential compression therapy, designed to aid in the prevention of deep vein thrombosis (DVT). This system, widely utilized in healthcare settings, employs inflatable sleeves to gently compress the limbs, promoting healthy blood circulation.
This user manual serves as a vital resource for healthcare professionals, providing detailed guidance on the proper setup, operation, and maintenance of the SCD 700 system. Access to the full operation and service manual, available online as a PDF, is crucial for understanding all aspects of the device. The system stores recent alarm codes for troubleshooting, and a dedicated test mode assists in device evaluation.
What is Sequential Compression Therapy?
Sequential Compression Therapy (SCT) is a non-invasive medical technique employed to enhance venous return in the lower extremities. The Covidien Kendall SCD 700 Series utilizes this therapy by applying graduated, sequential compression to the legs and/or arms via inflatable sleeves.
This compression mimics the natural muscle contractions that assist blood flow, preventing venous stasis – a primary risk factor for deep vein thrombosis (DVT). By promoting circulation, SCT helps reduce swelling and discomfort. Understanding the principles of SCT is fundamental to effectively utilizing the SCD 700 system. Proper application, as detailed in the user manual, ensures optimal therapeutic benefit for patients at risk.
Key Features of the SCD 700 Series
The Covidien Kendall SCD 700 Series boasts several key features designed for ease of use and effective therapy. These include user-adjustable therapy parameters, allowing clinicians to tailor treatment to individual patient needs. The system stores the ten most recent alarm codes, aiding in troubleshooting and device analysis.
A built-in test mode facilitates system verification and performance checks. The controller unit is designed for intuitive operation, with clear displays and simple programming. Furthermore, the system offers a range of cuff sizes to ensure a comfortable and effective fit for diverse patient populations. Access to the full operation and service manual provides detailed guidance.

Understanding the System Components
The SCD 700 Series comprises a controller unit, compression sleeves in various sizes, and connecting tubing – essential elements for effective sequential compression therapy.
SCD 700 Controller Unit
The SCD 700 Controller Unit serves as the central hub for operating the sequential compression system. It features a user-friendly interface for programming therapy parameters, including compression level and cycle time. This unit diligently monitors system performance and displays alarm codes to alert clinicians to potential issues.
Importantly, the controller stores the ten most recent alarm codes, aiding in troubleshooting when devices are returned. A dedicated test access mode, detailed within the full operation manual, allows for comprehensive system checks. The controller is designed for reliable performance and integrates seamlessly with the SCD 700 sleeves and air compressor, ensuring consistent and effective therapy delivery. Proper operation is crucial for patient safety and optimal outcomes.
SCD 700 Sleeves (Cuff Types & Sizes)
SCD 700 Sleeves are integral to the system, delivering the sequential compression therapy. These cuffs are available in various types and sizes to accommodate diverse patient anatomies. Proper sleeve selection is paramount for effective treatment and patient comfort. Options include standard sleeves, as well as specialized designs for arms or legs.
Careful attention must be paid to sizing guidelines to ensure appropriate compression. Incorrectly sized sleeves can compromise therapy efficacy or cause discomfort. The user manual provides detailed information on selecting the correct cuff type and size based on limb circumference measurements. Maintaining sleeve integrity through proper cleaning and inspection is also essential for optimal performance and patient safety.
Air Compressor and Tubing
The SCD 700 Series utilizes an air compressor to inflate and deflate the compression sleeves, driving the sequential compression therapy. This compressor delivers controlled pressure, crucial for effective treatment. The system employs specialized tubing to connect the compressor to the sleeves, ensuring reliable air delivery.
Regular inspection of the tubing for kinks, leaks, or damage is vital for maintaining system functionality. The user manual details proper connection procedures and emphasizes the importance of secure fittings. Maintaining the compressor according to the recommended schedule ensures optimal performance and longevity. Proper handling and storage of both the compressor and tubing contribute to the overall safety and effectiveness of the SCD 700 system.

Setting Up the SCD 700 Series
Proper setup involves initial inspection, secure connection of sleeves and tubing, and performing system checks before powering on for optimal therapy.
Initial Inspection and Preparation

Before initiating therapy, a thorough inspection of the Covidien Kendall SCD 700 Series components is crucial. Carefully examine the controller unit, sleeves, and tubing for any signs of damage, such as cracks, tears, or punctures. Ensure all connections are secure and free from obstructions.
Verify the controller displays power and functions correctly. Confirm the sleeves are the appropriate size for the patient and are clean and dry. Inspect the tubing for kinks or blockages that could impede airflow.
Prepare the patient by explaining the procedure and addressing any concerns. Gather all necessary supplies, including the SCD 700 system, sleeves, and appropriate cleaning solutions. A prepared environment ensures a smooth and effective therapeutic process.
Connecting the Sleeves and Tubing
Proper connection of sleeves and tubing is vital for effective SCD 700 Series operation. Begin by securely attaching the proximal end of each sleeve to the designated ports on the controller unit. Ensure a firm, audible click confirms a secure connection.

Next, connect the distal ends of the sleeves to the corresponding ports on the air compressor tubing. Verify that the tubing is not kinked or twisted, allowing for unobstructed airflow. Double-check all connections to prevent leakage during therapy.
Confirm the correct sleeve is connected to the appropriate leg. A secure and leak-free system is essential for delivering consistent and reliable compression therapy.
Powering On and System Checks
To initiate operation, connect the power adapter to the SCD 700 controller and a suitable power outlet. Press the power button; the system will undergo internal self-checks. Observe the display panel for any error messages or indications of malfunction.
Allow the internal checks to complete before proceeding with therapy. The system will typically indicate readiness with a visual or auditory cue. Verify that the connected sleeves inflate and deflate according to the programmed settings.
If any alarms or errors are displayed, consult the troubleshooting section of this manual before initiating therapy. A successful system check ensures optimal performance and patient safety;

Operating the SCD 700 Series
Proper operation involves careful patient selection, correct sleeve application, and precise programming of therapy parameters for optimal sequential compression benefits.
Patient Selection Criteria
The SCD 700 Series is indicated for patients at risk of deep vein thrombosis (DVT), including those post-surgery, with limited mobility, or experiencing acute medical illness. Contraindications include acute myocardial infarction, unstable congestive heart failure, active DVT, pulmonary embolism, and severe peripheral vascular disease.
Careful assessment of each patient’s medical history and current condition is crucial before initiating therapy. Physicians should evaluate for any conditions that might preclude the use of sequential compression devices. Appropriate candidates will benefit from improved venous return and reduced risk of thromboembolic events. Always consult with a healthcare professional to determine suitability.
Monitoring patients closely during therapy is essential to observe for any adverse reactions or signs of discomfort. Adjust therapy parameters as needed based on individual patient response and tolerance.
Applying the Compression Sleeves
Proper application of the SCD sleeves is vital for effective therapy. Ensure the patient’s leg is dry and free of lotions. Begin by orienting the sleeve with the inflation ports positioned proximally (towards the thigh). Gently roll the sleeve onto the leg, ensuring a snug but not constricting fit.
Avoid wrinkles or bunching, as these can impede circulation. Overlap the sleeve slightly at the proximal end and secure it with the provided straps. Confirm that the sleeve covers the entire limb segment as indicated by the sizing guidelines.
Inspect the skin for any signs of irritation or pressure points after application. Regularly assess the limb during therapy to ensure continued comfort and proper function of the device.
Programming Therapy Parameters
The SCD 700 Series allows customization of therapy based on patient needs. Access the programming mode via the controller unit’s interface. Key parameters include compression level, cycle time, and therapy duration. Compression levels typically range from low to high, adjusted based on patient tolerance and physician orders.
Cycle time determines the inflation/deflation frequency, influencing venous return. Therapy duration is set according to the prescribed treatment plan. Carefully input these parameters, verifying accuracy before initiating therapy.
Consider patient-specific factors like limb circumference and medical history when selecting settings. Document all programmed parameters for accurate record-keeping and consistent treatment;

Troubleshooting and Alarm Codes
The SCD 700 Series stores recent alarm codes for troubleshooting. Refer to the manual for code meanings and resolution steps to address system issues promptly.
Common Alarm Codes and Their Meanings
Understanding alarm codes is crucial for effective troubleshooting of the Covidien Kendall SCD 700 Series. The system diligently records the ten most recent alarm occurrences, providing valuable diagnostic data. While specific codes vary, common alerts indicate issues like sleeve disconnection, detected occlusion within the cuff, or low battery conditions.
A “Sleeve Disconnected” alarm necessitates checking connections. An “Occlusion” alarm suggests excessive pressure or a blockage; adjust settings or reposition the sleeve. “Low Battery” requires immediate charging or replacement. The user manual provides a complete list, detailing each code’s precise meaning and recommended corrective actions. Ignoring alarms can compromise therapy; prompt attention ensures patient safety and optimal device performance.
Troubleshooting Steps for Frequent Issues
Addressing common issues with the Covidien Kendall SCD 700 Series is straightforward. If the device doesn’t power on, verify the power cord connection and battery charge. For alarms indicating sleeve problems, ensure secure tubing connections and proper sleeve application. If an occlusion alarm persists, gently reposition the sleeve and reduce pressure settings.
Review the recorded alarm codes – the system stores the ten most recent – for clues. Consult the user manual for detailed troubleshooting guidance specific to each alarm. Regular inspection of sleeves for damage and tubing for kinks prevents recurring problems. If issues remain unresolved, contact qualified biomedical support for assistance, ensuring continued effective therapy.
Accessing the Test Mode
The Kendall SCD 700 Series incorporates a test access mode for verifying system functionality. This diagnostic tool allows healthcare professionals to assess the controller’s performance and identify potential issues. Accessing this mode, detailed within the operation and service manual, involves a specific sequence of button presses on the controller unit.
During test mode, the system cycles through various operational checks, confirming proper inflation and deflation of sleeves. This ensures accurate pressure delivery and reliable operation. Utilizing test mode before patient use and after maintenance confirms the device meets performance standards. Refer to the manual for precise instructions and interpretation of test results.

Maintenance and Safety
Regular cleaning and disinfection, alongside proper battery handling, are crucial for SCD 700 Series longevity and patient safety, as outlined in the manual.
Cleaning and Disinfection Procedures
Maintaining cleanliness is paramount for preventing healthcare-associated infections. The Covidien Kendall SCD 700 Series requires routine cleaning and disinfection following each patient use, and as needed during operation. Always disconnect the device from the power source before cleaning.
Use a mild detergent and water to wipe down the controller unit and sleeves. Avoid abrasive cleaners or harsh chemicals, as these can damage the equipment. Ensure sleeves are thoroughly dried before reapplication.
Disinfection can be achieved using an EPA-registered disinfectant compatible with the sleeve material. Follow the disinfectant manufacturer’s instructions regarding contact time and dilution. Inspect sleeves regularly for signs of wear and tear, replacing them as necessary. Refer to the full operation and service manual for detailed guidance.
Battery Usage and Replacement
The Covidien Kendall SCD 700 Series utilizes internal batteries for portable operation, providing uninterrupted therapy during power outages or patient transport. Battery life varies depending on usage and settings. The controller displays a low battery indicator when replacement is needed.
Only use Covidien-approved replacement batteries to ensure optimal performance and prevent damage to the device. Refer to the operation and service manual for specific battery type and replacement instructions;
Proper battery handling is crucial; avoid short-circuiting or exposing batteries to extreme temperatures. Dispose of used batteries according to local regulations. Regularly check battery functionality to maintain reliable operation of the compression system.
Safety Precautions and Contraindications
Prior to SCD 700 Series use, carefully review all safety precautions and contraindications outlined in this manual. This system is intended for trained healthcare professionals only. Never use on patients with acute deep vein thrombosis (DVT) or pulmonary embolism.
Inspect sleeves for damage before each application. Do not apply over open wounds, skin grafts, or areas of infection. Monitor patients closely for signs of skin irritation or discomfort.
Ensure proper grounding and avoid operating the device in wet environments. Disconnect from power during cleaning. Consult the full operation and service manual for a complete list of contraindications and safety guidelines.

Technical Specifications
The SCD 700 Series details electrical requirements, dimensions, weight, and operating environment parameters for optimal performance and safe utilization of the device.
Electrical Requirements

The Covidien Kendall SCD 700 Series is designed for use with standard electrical power sources. Typically, the device operates on 100-240 VAC, 50/60 Hz, ensuring compatibility across various international standards.
It’s crucial to verify the power supply matches these specifications before connecting the unit. The system incorporates a power adapter for converting the input voltage to the required DC voltage for operation.
Important safety considerations include using a properly grounded outlet and avoiding the use of extension cords or adapters that do not meet safety standards. The device also features internal overcurrent protection to prevent damage from power surges. Always refer to the device label for specific electrical ratings.
Dimensions and Weight
The Covidien Kendall SCD 700 Series controller unit is designed for portability and ease of use in various clinical settings. Its compact dimensions typically measure approximately 6 inches (height) x 8 inches (width) x 4 inches (depth), though slight variations may occur depending on the specific model.
The weight of the controller unit is generally around 2 to 3 pounds, making it lightweight for transportation and mounting.
Sleeve dimensions vary based on size (standard, wide calf, thigh-high) and are designed to accommodate a broad range of patient leg circumferences. Detailed sleeve sizing charts are available in the full operation manual. Accurate dimensions are vital for proper compression therapy.
Operating Environment
The Covidien Kendall SCD 700 Series is intended for use in standard healthcare environments. Optimal performance is achieved within a temperature range of 50°F to 95°F (10°C to 35°C). Avoid operating the device in excessively hot or cold conditions, as this may affect its functionality and lifespan.
Humidity levels should be maintained between 15% and 95% relative humidity, non-condensing. Exposure to excessive moisture or condensation can damage the internal components.
The device is designed for indoor use only and should not be exposed to direct sunlight, rain, or other forms of weather. Ensure adequate ventilation around the unit to prevent overheating. Refer to the full manual for detailed environmental specifications.